D31FBE02CC4NF00 Parker // Proportional Valve

Application and Usage Guidelines

The D31FBE02CC4NF00 is a pilot-operated proportional directional control valve featuring onboard electronics, widely utilized in industrial hydraulic systems for precise flow and direction regulation. It excels in applications requiring stepless speed control and smooth acceleration. Important: Maintain fluid cleanliness at ISO 4406 (18/16/13) levels to prevent pilot stage clogging. Ensure the power supply (18–30 VDC) is surge-free. Because this model relies on a pilot pressure of at least 30 bar, verify your system’s minimum supply pressure before operation. During installation, ensure the 6+PE connector is properly shielded to avoid electromagnetic interference with the 0–10V input signal. Regular inspection of seals and electrical terminals is essential to ensure long-term reliability and performance.

Original price was: $5,655.00.Current price is: $2,755.00.

Share to :

FeatureSpecification
Product ModelD31FBE02CC4NF00
ManufacturerParker Hannifin
Valve TypePilot Operated Proportional Directional Control Valve
Nominal SizeNG10 / CETOP 05
Max Operating Pressure350 bar (5000 PSI)
Max Flow Rate75 L/min
ElectronicsOnboard Electronics (OBE)
Signal Input0 – ±10 V
Seal MaterialNBR
Connection Type6 + PE

                                                          📦  Warranty&Reture Policy:

🛡️  1、One year warranty. If the product malfunctioned under proper usage per instructions manual within the warranty period, please contact us to obtain shipping instructions and send it back at your shipping costs.
🔍 2、14days evaluation and investigation takes placed after receiving yourreturn item.

 

                                         ❓ Frequently Asked Questions: Moog Proportional Valves

1. 🔍 Why is fluid cleanliness so critical, and what is the recommended standard?

First and foremost, Moog proportional and servo valves feature highly sensitive pilot stages, such as ServoJet® or nozzle-flapper systems, which operate with extremely tight tolerances. Consequently, even microscopic particulate contamination can jam spools, cause erratic control, or accelerate premature wear.

To prevent these issues, operators must maintain a fluid cleanliness level of ISO 4406 < 14/11 for an extended service life (or at least ISO 4406 < 16/13 for standard operations). In addition, you should always install a 10 $mu m$ absolute filter ($beta_{10} ge 75$) without a bypass line directly upstream from the valve inlet to catch harmful debris before it enters the system.

2. ⚡ What are the typical command signal options, and how do I prevent signal interference?

Generally speaking, modern Moog proportional valves (like the D661 series) utilize Integrated Electronics (OBE) and accept standard analog command signals, most commonly $pm$10 V or 4 to 20 mA. While voltage signals offer convenience for basic setups, current signals (4 to 20 mA) provide superior resistance to voltage drops and signal degradation during long-distance transmissions.

To ensure optimal performance, you must mitigate Electromagnetic Interference (EMI). Specifically, always use properly shielded cables and connect them correctly to the 6+PE electrical connector housing. Furthermore, keep all low-voltage signal wiring physically separated from high-voltage power lines to maintain absolute signal integrity.

3. 🛡️ What happens during a power failure, and how does the fail-safe logic work?

In the event of a sudden power loss or cable break, system safety becomes the top priority. Fortunately, Moog engineers built-in fail-safe centering logic layouts into these valves. Depending on your specific model configuration, internal spring forces or pilot pressure will automatically shift the valve spool to a predetermined safe position—such as a completely closed (neutral) position or a specific flow path.

Therefore, before initiating your very first system startup, you must verify the exact fail-safe code on your valve’s nameplate. By doing so, you ensure that your machinery’s emergency shut-down behavior aligns perfectly with your plant’s operational safety protocols.