| Parameter | Specification Details |
| Product Series | D31FP Series (High Dynamics) |
| Nominal Size | NG10 / CETOP 05 |
| Max Operating Pressure | 350 bar (5075 PSI) |
| Nominal Flow Rate | 90 L/min (at $\Delta p$ = 5 bar per control edge) |
| Maximum Flow Rate | 250 L/min |
| Spool Code | E52 (Zerolap / 4-way) |
| Defined Position at Power Down | P-B / A-T (Code D) |
| Actuation Type | VCD®-actuator (Pilot stage) |
| Command Signal | 0 to ±10 V (Voltage Input) |
| Pilot Inlet / Drain | Internal / Internal (Code 4) |
| Seal Material | NBR (Nitrile Rubber) |
| Electronics Type | Integrated Digital Onboard Electronics (OBE) |
| Response Time | Approx. 10 ms (Step response 0–100%) |
| Hysteresis | < 0.1% |
| Protection Rating | IP65 (acc. to EN 60529) |
| Weight | 11.3 kg |
D31FPE52DB4NK00 Parker Proportional Valve
Typical Application Scenarios
The D31FPE is designed for industrial applications that require high flow rates paired with “servo-class” precision:
-
Precision Press Control: Used in high-speed forging, bending, or stamping presses where synchronization of multiple cylinders is required.
-
Plastic Injection Molding: Manages critical speed and pressure control phases in large-scale molding machines.
-
Testing Rigs: Ideal for dynamic simulators or structural test benches that require a high frequency response to mimic real-world vibrations or loads.
-
Steel & Paper Mills: Controlling heavy-duty rollers or tensioning systems where millisecond response times prevent material breakage.
Important Precautions (Usage Notes)
-
Internal Pilot Supply (Code 4): Since this model is configured for Internal Pilot Inlet and Internal Drain, you must ensure that the pressure in the P-line never drops below the minimum required pilot pressure (20 bar) during operation. If P-line pressure is too low, the valve will not shift correctly.
-
Zerolap Spool Sensitivity: The E52 (Zerolap) spool is designed for closed-loop control systems. It has no deadband at the center, meaning even a tiny signal change results in flow. This makes it very precise but also very sensitive to signal noise—ensure your PLC signal is clean.
-
Filtration is Critical: The VCD pilot stage and Zerolap spool have extremely tight tolerances. You must maintain a fluid cleanliness level of ISO 4406 18/16/13. Using a high-quality pressure filter (3–10 $\mu$m) is mandatory to prevent premature wear or “sticking.”
-
Power Down Behavior: Note the Code D fail-safe: in the event of power loss, the spool is designed to move to the P-B / A-T position. Ensure this movement is safe for your specific machine configuration.
-
Shielded Cables: To protect the digital onboard electronics (OBE), use shielded cables for the command signal and ground them at the cabinet side to avoid electromagnetic interference (EMI).
$4,850.00 原价为:$4,850.00。$4,356.00当前价格为:$4,356.00。
Share to :




评价
目前还没有评价