🇺🇸 EN ⌃

D41VW004C1VJW Parker // Proportional Valve

Application and Usage Guidelines

The D41VW004C1VJW is a high-performance solenoid-operated directional control valve widely used in industrial hydraulic systems for actuating cylinders and motors. It is well-suited for high-pressure applications requiring reliable flow direction switching. Important: Ensure the hydraulic fluid is maintained at ISO 4406 (18/16/13) cleanliness standards to prevent spool sticking. Because this model utilizes Viton seals, it is compatible with a broad range of fluids, but verify chemical compatibility for your specific application. Ensure the 24 VDC power supply matches the solenoid ratings to avoid coil burnout. Regularly check the electrical connections for secure seating and moisture ingress, as the valve is rated for demanding environments. Proper maintenance of the 350 bar rated seals is critical to ensuring long-term, leak-free operation.

Original price was: $5,655.00.Current price is: $2,415.00.

Share to :

Feature Specification
Product Model D41VW004C1VJW
Manufacturer Parker Hannifin
Valve Type Solenoid Operated Directional Control Valve
Nominal Size NG10 / CETOP 05
Max Operating Pressure 350 bar (5000 PSI)
Max Tank Pressure 210 bar (3000 PSI)
Max Flow Rate 150 L/min (40 GPM)
Spool Type 004 (Cylinder port blocked in center)
Solenoid Voltage 24 VDC
Seal Material Viton (Fluorocarbon)
Electrical Connection DIN 43650 (Standard)

                                                          📦  Warranty&Reture Policy:

🛡️  1、One year warranty. If the product malfunctioned under proper usage per instructions manual within the warranty period, please contact us to obtain shipping instructions and send it back at your shipping costs.
🔍 2、14days evaluation and investigation takes placed after receiving yourreturn item.

 

                                         ❓ Frequently Asked Questions: Moog Proportional Valves

1. 🔍 Why is fluid cleanliness so critical, and what is the recommended standard?

First and foremost, Moog proportional and servo valves feature highly sensitive pilot stages, such as ServoJet® or nozzle-flapper systems, which operate with extremely tight tolerances. Consequently, even microscopic particulate contamination can jam spools, cause erratic control, or accelerate premature wear.

To prevent these issues, operators must maintain a fluid cleanliness level of ISO 4406 < 14/11 for an extended service life (or at least ISO 4406 < 16/13 for standard operations). In addition, you should always install a 10 $mu m$ absolute filter ($beta_{10} ge 75$) without a bypass line directly upstream from the valve inlet to catch harmful debris before it enters the system.

2. ⚡ What are the typical command signal options, and how do I prevent signal interference?

Generally speaking, modern Moog proportional valves (like the D661 series) utilize Integrated Electronics (OBE) and accept standard analog command signals, most commonly $pm$10 V or 4 to 20 mA. While voltage signals offer convenience for basic setups, current signals (4 to 20 mA) provide superior resistance to voltage drops and signal degradation during long-distance transmissions.

To ensure optimal performance, you must mitigate Electromagnetic Interference (EMI). Specifically, always use properly shielded cables and connect them correctly to the 6+PE electrical connector housing. Furthermore, keep all low-voltage signal wiring physically separated from high-voltage power lines to maintain absolute signal integrity.

3. 🛡️ What happens during a power failure, and how does the fail-safe logic work?

In the event of a sudden power loss or cable break, system safety becomes the top priority. Fortunately, Moog engineers built-in fail-safe centering logic layouts into these valves. Depending on your specific model configuration, internal spring forces or pilot pressure will automatically shift the valve spool to a predetermined safe position—such as a completely closed (neutral) position or a specific flow path.

Therefore, before initiating your very first system startup, you must verify the exact fail-safe code on your valve’s nameplate. By doing so, you ensure that your machinery’s emergency shut-down behavior aligns perfectly with your plant’s operational safety protocols.