| Parameter | Specification Details |
| Product Series | D91FC Series (Proportional Directional Control) |
| Nominal Size | NG25 / CETOP 08 |
| Maximum Operating Pressure | 350 bar (5075 PSI) (Ports P, A, B, X) |
| Nominal Flow Rate | 450 L/min (at $\Delta p$ = 5 bar per control edge) |
| Spool Code | B32 (Overlap spool, 4-way, 3-position) |
| Electronics Type | Integrated Digital Onboard Electronics (OBE) |
| Command Signal | 0 to ±10 V (Voltage Input) |
| Pilot Inlet / Drain | Internal / External (Code 1) |
| Hysteresis | < 0.1% |
| Response Time | Approx. 6.7 ms (Step response) |
| Seal Material | NBR (Nitrile Rubber) |
| Power Supply | 18 to 30 VDC (Ripple < 5%) |
| Protection Rating | IP65 (acc. to EN 60529) |
| Weight | 21.0 kg |
| Operating Temperature | -20 °C to +60 °C (Ambient) |
D91FCB32HC1NS00 Parker Proportional Valve
Typical Application Scenarios
The D91FC series is designed for heavy-duty industrial applications where high flow volumes must be managed with high accuracy:
-
Die Casting & Injection Molding: Controls high-flow clamping and injection cylinders where rapid movement and precise end-positioning are required.
-
Large Hydraulic Presses: Manages the main ram movement in forging or stamping presses for synchronized and smooth motion.
-
Steel & Primary Metal Processing: Used in rolling mills or heavy handling equipment that requires rugged, high-capacity flow control.
-
Marine & Offshore: Ideal for large winch systems or steering gear requiring robust proportional control in harsh environments.
Important Precautions (Usage Notes)
-
Filtration Standards: Due to the high-definition position feedback and pilot-operated design, this valve is sensitive to contamination. Maintain oil cleanliness at ISO 4406 18/16/13 (NAS 1638: 7) or better.
-
External Drain (Port Y): This configuration (Code 1) uses an external pilot drain. Ensure the Y-port is connected directly to the tank with minimal backpressure (ideally < 2 bar). Excessive backpressure in the drain line will cause inaccuracies in spool positioning.
-
Pilot Pressure Requirements: Since the valve is pilot-operated, ensure a minimum pilot pressure of 20 bar is always available to shift the main spool, even if the P-port pressure drops.
-
Electrical Grounding: Use shielded cables for the 0-10V command signal and ground the shield only at the control cabinet side. This is vital to protect the digital electronics from electromagnetic interference (EMI) typical in industrial plants.
-
Mounting Surface: Given the weight of 21 kg and the high-precision spool, ensure the mounting manifold is perfectly flat and the mounting bolts are tightened to the specified torque to prevent body distortion.
$3,678.00 Original price was: $3,678.00.$3,245.00Current price is: $3,245.00.
Share to :
Related products
-
Parker Valve
TDP080EH99C2NB0 2-Way High-Response Valve – Series TDP
Rated 0 out of 5$18,564.00Original price was: $18,564.00.$13,856.00Current price is: $13,856.00. Add to basket -
Parker Valve
TDP063EH79C2NB0 2-Way High-Response Valve – Series TDP
$9,580.00 Add to basketRated 0 out of 5 -
Parker Valve
TDP032EH99C2NE0 2-Way High-Response Valve – Series TDP
$2,780.00 Add to basketRated 0 out of 5 -
Parker Valve
TDP032EH99C2VB0 2-Way High-Response Valve – Series TDP
$2,780.00 Add to basketRated 0 out of 5




Reviews
There are no reviews yet.